Ajit Vadakayil

  • Subscribe to our RSS feed.
  • Twitter
  • StumbleUpon
  • Reddit
  • Facebook
  • Digg

Monday, 9 July 2012

CARGO TANK INTERNAL INSPECTION ON CHEMICAL TANKERS- CAPT AJIT VADAKAYIL

Posted on 10:09 by Unknown

CARGO TANK INTERNAL INSPECTION ON CHEMICAL TANKERS- CAPT AJIT VADAKAYIL


Chemical tankers will clean the cargo tanks and associated pipeline systems prior to declaring NOR and arrival at the load berth.



In modern times , it is essential to take plenty of pictures from all angles , with all ports open to allow daylight in.  Once you load the pictures it in your computer, you can be surprised that the camera has pinged what your eyes could not --- and you can zoom in too.

A smart tank inspector knows the position of your tankcleaning machines, the blind sectors of the jet and if you gave given machine drops .  He knows where to look.

Special attention should be paid to the condition of the tank coating in the case of epoxy coated tanks and, in particular, to the presence of blisters and flaking of the coating.


Unbroken blisters may contain residues from an earlier cargo as will loose or flaking coating.


Depending on the charterer or shipper requirements, the inspector may be asked to estimate the percentage of coating missing or damaged.


Reference to the vessel’s previous cargoes can have a bearing on the further action required from the crew when determining the likely effect the condition of the coating might have on the cargo to be loaded.


Attention should also be paid to the cargo tank, pipes, drop lines, pump casings, suction wells and heating coils. These items can form shadow areas and often receive less than adequate attention during tank washing.


Inspectors cannot, of course, visually inspect the internal condition of pipelines for their full length and the inspection report should clearly state the applicable limitations.


Vent and inert gas lines are usually visible at the tank entry point and could contain prior cargos, polymerized material, or washing residues, that if present, could contribute to contamination.


Deck lines will have drain points and these should be opened in case residues from tank washing operations or prior cargos are present.


Wall wash test by inspectors/ suryeyors :--

Tank surfaces must be dry.

Discoloured or broken coating sections on tank walls should be sampled as follows:

Where such areas are less than 20% of total surface area (excluding deckheads), the washings should be included with those of the rest of the tank.

Non typical areas should be sampled and tested separately. Samples should be tested in a shore based laboratory.

The minimum number of areas to wall wash depends on the tank capacity.

Tank capacity less than 500 cubic metres--     5 areas

Tank capacity 500 to 1000 cubic metres--      7 areas

Tank capacity greater that 1000 cubic metres--       9 areas


Wall wash sampling procedures may cause a previously gas free tank to develop an unsafe atmosphere and personal protective gear should always be worn and breathing apparatus may be required.


There are limitations on the extent to which inspectors can visually inspect all parts of the loading system, vessel and shore, and so they will  inquire about the steps taken by the vessel to avoid or reduce the risk of contamination.


Loading/discharge manifolds, vents, and inert gas lines  can only be inspected where visually accessible.  Extensive areas of the pump and piping systems can only be assessed on the basis of information obtained from the Chief Officer in respect of tank cleaning operations and previous cargoes.

 Prior to loading “first foots” in tanks , an initial shore line sample should be drawn and visually examined to ensure the cargo is clean and bright and free of suspended matter. This first foot sample at the manifold must be drawn with the manifold valve SHUT ( you cant do this for screw pumps and reciprocating piston pumps )


Subject to wall wash tests (where applicable) and receiving laboratory clearance, the vessel will then be able to start loading “first foots”.


First Foot samples are required to determine whether any contaminants within the vessels loading systems have survived cleaning regimes that might have a detrimental effect on the cargo to be loaded.


Cargo Tank Coating Suitability

 The following is to  understanding potential contamination problems that may arise with chemical cargoes.


Zinc silicate, phenolic epoxies and pure epoxies are the most commonly used generic coating systems in cargo tanks for the carriage of chemicals.

 They vary in their resistance to cargoes and all have limitations in carriage.

 The principal limitation in the use of zinc silicates is that they are only suitable in a narrow pH

range of approximately 5.0 to 9.0.


Phenolic epoxies are generally able to carry a wider range of low molecular weight cargoes and have a higher free fatty acid resistance

 The cargo resistance of coatings of the same generic type can vary between manufacturers and, hence, the manufacturers Resistance Lists usually available aboard the vessel should be consulted should there be any doubts as to suitability of any particular cargo.

Some coatings are temperature sensitive.  Cargo carriage requirements may require heating, and temperature control should match the coating operability range.

Organic epoxy coatings have the propensity to absorb cargoes during a loaded passage. The contamination potential to a subsequent cargo is therefore considerable as:

Large quantities can be retained

The amount retained after different time periods is not well defined

Variable absorption/desorption characteristics are found between different coating types

Variable absorption/desorption characteristics are found within the same generic types from different manufacturers.

Different rates of absorption/desorption are found between different cargoes

Factors such as coating thickness, temperature and tank cleaning also have an influence on absorption and desorption.

With some chemical cargoes, absorbed material can survive both further intermediate cargoes as well as extensive tank cleaning operations

The shore tank inspector is NOT a bird. He goes down the tank ladder . On the way, he will touch and rub certain areas. Be sure that these areas are good.  

At the tank dome itself  , before entering , the shore surveyor  will smell the tank, and sometimes this smell could come from dirty gasket of the tank dome cover. He will refuse to enter if the previous cargo has any carcinogenic percentage .

Cargo hoses used for looping forms part of the pipelines . Number them and have a list of the last 3 cargoes handles by these hoses.

If the previous cargo was insoluble in water, check the threads of all bolts inside the tank, minutely.

Sometimes it so transpires that after Methanol / potable Ethanol discharge, the tank was vented and the tank fails at the load port for the same cargo, to be loaded again. Just make sure the horizontals and slanted surfaces do NOT have any sediment, by rubbing a wet black/ white cotton lint free cloth.

Nowadays surveyors are hand in glove with shippers ( for a ulterior reasons ) and they fail the tanks for moisture condensation. Don’t be naïve.  The principle to apply here is -- warm moist air, always condenses on a cold steel bulkhead. This is the reason why chemical tanker-men cannot be dimwits.



CAPT AJIT VADAKAYIL
29 years in command
Email ThisBlogThis!Share to XShare to FacebookShare to Pinterest
Posted in | No comments
Newer Post Older Post Home

0 comments:

Post a Comment

Subscribe to: Post Comments (Atom)

Popular Posts

  • SURYA NAMASKAR, THE 11000 YEAR OLD VEDIC SUN SALUTATION - CAPT AJIT VADAKAYIL
    This post is the most valuable piece on Surya Namaskar you will find in any language other that Sanskrit. Thousands of pretenders have flood...
  • SHUKRACHARYA IS AHURA MAZDA GOD OF THE PARSIS, INDIAN PROPHET ZOROASTER WROTE ZEND AVESTA – CAPT AJIT VADAKAYIL
    ZOROASTER OF 600 BC WHO MIRRORED HINDUISM AND CONVERTED DEVAS INTO BAD AND ASURAS INTO GOOD ,   F RENCH JEW AND ROTHSCHILD AGENT ABRAHAM HY...
  • EXHUMING DIRTY SECRETS OF HOLODOMOR , BOLSHEVIK REVOLUTION, AND THE GULAG – CAPT AJIT VADAKAYIL
    LEST WE FORGET ,  THE ALL JEWISH ROTHSCHILD CONTROLLED ROLE  OF   GENRIKH GRIGORYEVICH YAGODA ,  LAZAR MOISEYEVICH KAGANOVICH ,   NAFTALY...
  • THE WORST RACISTS ON PLANET EARTH- CAPT AJIT VADAKAYIL
    WHAT NAMBOOTHIRI DOT COM WEBSITE WONT TELL YOU —   MOST DISGRACEFUL AND FOUL RACIST SYSTEM IN KERALA INVENTED BY NAMBOOTHIRI BRAHMINS. Yes,...
  • SHOCKING LEGACY OF MAD COW DISEASE – CAPT AJIT VADAKAYIL
    MARGARET THATCHER COVERED UP MAD COW DISEASE FOR YEARS ,   VARIANT   CREUTZFELDT JACOB DISEASE,  NORMAL PRESSURE HYDROCEPHALUS ,   LONG IN...
  • OATS AND A2 MILK PORRIDGE , KARAMBA THE BREAKFAST OF ANCIENT KALARI WARRIORS - CAPT AJIT VADAKAYIL
    BENEFITS OF JAU OR OATS IN 6100 YEAR OLD ASTANGA HRIDAYAM SAMHITA ,   VAGHBATA THE DISCIPLE OF FATHER OF MEDICINE CHARAKA ,   BREAKFAST OF O...
  • MARINE ENGINEERING SELF EXAMINER, AUX MACHINERY- CAPT AJIT VADAKAYIL
    MARINE ENGINEERING SELF EXAMINER, AUX MACHINERY-  CAPT AJIT VADAKAYIL The following is a SELF EXAMINER questionnaire . If you are marine en...
  • DIFFERENCE BETWEEN A BUDDHA AND MAHAVIRA STATUE- CAPT AJIT VADAKAYIL
    SRIVATSA MARK OF MAHAVIRA ,    LEFT HANDED SWASTIKA OF BUDDHA ,   KAUSTUBHA MANI FROM SAMUDRA MANTHAN  –  CAPT AJIT VADAKAYIL Several deca...
  • 12 STRAND DNA ACTIVATION MANTRA -- CAPT AJIT VADAKAYIL
    This is in reponse to a query in my post IMHOTEP --on how to activate the dormant 12 strand DNA-after 21st dec 2012. All of us have only 2 s...
  • STAINLESS STEEL CARGO TANK LINING ON CHEMICAL TANKERS- CAPT AJIT VADAKAYIL
    SS SOLID AND CLAD SUS 316 LN , SUS 317 LN The oldest example of stainless steel is antiquated as the iron pillar of Delhi erected 1600 ye...

Blog Archive

  • ►  2013 (115)
    • ►  December (1)
    • ►  November (8)
    • ►  October (11)
    • ►  September (6)
    • ►  August (7)
    • ►  July (8)
    • ►  June (11)
    • ►  May (12)
    • ►  April (11)
    • ►  March (12)
    • ►  February (15)
    • ►  January (13)
  • ▼  2012 (174)
    • ►  December (7)
    • ►  November (17)
    • ►  October (22)
    • ►  September (23)
    • ►  August (27)
    • ▼  July (24)
      • MY EXPERIENCE AT MUNDRA PORT , ADANI SEZ- CAPT AJ...
      • LALA LAJPAT RAI, THE LION OF PUNJAB- CAPT AJIT VAD...
      • TUM MILE , CANT STOP LOVIN' YOU -- CAPT AJIT VAD...
      • CHEMICAL HAZARDS ON CHEMICAL TANKERS- CAPT AJIT ...
      • UNSUNG HEROES OF INA- CAPT AJIT VADAKAYIL
      • MAYA , INCA , AZTEC CIVILIZATIONS DECODED - CAPT A...
      • JEWISH RUSSIAN MAFIA - CAPT AJIT VADAKAYIL
      • FRANCISCO PIZARRO , HERNAN CORTES, GENOCIDE BY SMA...
      • SCAC CODES ON CHEMICAL TANKERS- CAPT AJIT VADAKAYIL
      • ODE TO RAJESH KHANNA- CAPT AJIT VADAKAYIL
      • WHAT DO I STAND FOR? - CAPT AJIT VADAKAYIL
      • VOLTA , GALVANI , THE ELECTRICAL BATTERY AND RISHI...
      • CARGO TANK INTERNAL INSPECTION ON CHEMICAL TANKERS...
      • MANMOHAN SINGH THE UNDERACHIEVER, TIME MAGAZINE - ...
      • LEANDER BHUPATI SANIA EGO CLASHES AND INDIAN TV ME...
      • BRAHMA AND SARAWATI, ABRAHAM AND SARA - CAPT AJIT ...
      • THE KOREAN BRAHMINS, KIM HEO CLAN - CAPT AJIT VADA...
      • AN EXAMPLE OF THE WORD RANT- CAPT AJIT VADAKAYIL
      • THE NAIVE SAILOR, SUPERSTRIP - CAPT AJIT VADAKAYIL
      • HIGGS BOSON , GOD PARTICLE NONSENSE, SOME MORE FUN...
      • HYDRAULIC SAFETY ON CHEMICAL TANKERS- CAPT AJIT V...
      • KING COBRA AND SNAKE TEMPLES OF KERALA- CAPT AJIT ...
      • SCRAP THE SETHUSAMUDRAM PROJECT, NOW - CAPT AJIT V...
      • INDIA'S WORST PRESIDENT EVER ? SO WHAT , SHE COOK...
    • ►  June (30)
    • ►  May (24)
  • ►  2011 (210)
    • ►  December (23)
    • ►  November (38)
    • ►  October (26)
    • ►  September (32)
    • ►  August (45)
    • ►  July (35)
    • ►  March (4)
    • ►  February (7)
Powered by Blogger.

About Me

Unknown
View my complete profile